Technical Data
Basic Version | Extended Version | |
for internal production control by the | up to three automatic successive tests | |
Measurement Mode | single test for one | random choice of temperature |
Measurement | 40 °C | random choice of temperature |
Temperature Difference | 10 K | random choice in range of 10…15 K |
Measurement Range | λ = 10...100 mW/m·K | λ = 10...100 mW/m·K |
Specimen Length | 1000 mm | 1000 mm |
Measurement Zone | middle pipe section 600 mm in length | middle pipe section 600 mm in length |
End Section | right and left hand side of test area, | right and left hand side of test area, |
Reproducibility | < 1,0 % (mostly < 0,5 %) | < 1,0 % (mostly < 0,5 %) |
Measurement Accuracy | < 2,0 % (mostly < 1,0...1,5 %) | < 2,0 % (mostly < 1,0...1,5 %) |
Dimensions | 131 x 42 x 60 cm³ | 131 x 42 x 60 cm³ |
Mass | ca. 30 kg | ca. 30 kg |
Power Supply | 230 V / 50 Hz | 230 V / 50 Hz |
Power Consumption | max. 250 W | max. 250 W |
Protection Class / | I / IP 20 | I / IP 20 |
Cooling aggregate | 4 high-performance peltier modules | 8 high-performance peltier modules |